ArgonØ – Specifications

Technical Specifications & Maintenance

Process – Argon Flowrate

<250 Nl/min

Utility – Power

380 – 480V    3ph    30amps

Maximum Dimensions

Width – 2000mm  Depth – 900mm  Height – 2000mm

Process – Argon Flowrate

<200 Nl/min

Utility – Power

400 – 440V    3ph    10amps

Maximum Dimensions

Width – 900mm  Depth – 500mm  Height – 1300mm


Click to enlarge

 

 

 

 

 

 

 

This schedule covers the works associated with a single ArgonØ and 4 recovery modules.

Weekly

Visual check of all equipment.

Monthly

Check oil in Vacuum pump and top up where required Change recovery module compressor filter Clean all air intake filters

Quarterly

Refurbish gas compressors in recovery modules and ArgonØ Remove and clean back pressure control valve in recovery modules Check and clean cooling radiators in recovery modules and ArgonØ

Every Three Years

Replace all compressors

Every Five Years

Replace CLC reactor column assemblies